I repaired a chinese grid tie inverter for small solar systems, Input 50-100V, Output 230V 300W. The failure was in the reference voltage inside the µC ATMega8, it dropped down arbitrary. To be able to find this failure, I had to re-engineer the complete set and had to draw the schematics by my own.
I repaired a chinese grid tie inverter for small solar systems, Input 50-100V, Output 230V 300W. The failure was in the reference voltage inside the µC ATMega8, it dropped down arbitrary. To be able to find this failure, I had to re-engineer the complete set and had to draw the schematics by my own. I share this here to help other insane electrophile humans to get familiar with grid tie inverters.
Veuillez saisir votre adresse électronique. Les instructions de réinitialisation de votre mot de passe vous seront immédiatement envoyées par courriel.
Elektor Magazine est depuis 65 ans l’une des principales sources d’information en électronique pour les ingénieurs, les concepteurs, les start-ups et les entreprises. Notre magazine est soutenu par une communauté active d’ingénieurs en électronique – des étudiants aux professionnels – passionnés par la conception et le partage d’idées innovantes.
Pour eux, nous publions chaque année des centaines de contenus sous différents formats, tels que des articles, des vidéos, des webinaires et d’autres formats d’apprentissage. Notre mission est de partager les connaissances de toutes les manières possibles et d’inspirer les lecteurs avec les dernières évolutions du secteur de l’ingénierie électrique.